W 6L32
Описание двигателя Wärtsilä 6L32
Wärtsilä 6L32 четырехтактный, нереверсивный, рядный, 6-ти цилиндровый дизельный двигатель с турбонаддувом и промежуточным охлаждением, с прямым впрыском топлива.
Технические характеристики
Wärtsilä 6L32 IMO Tier 2 |
|
AE/DE |
AE/DE |
ME |
AE/DE |
AE/DE |
ME |
Engine speed |
RPM |
720 |
750 |
750 |
720 |
750 |
750 |
Cylinder output |
kW/cyl |
480 |
500 |
500 |
550 |
580 |
580 |
Engine output |
kW |
2880 |
3000 |
3000 |
3300 |
3480 |
3480 |
Mean effective pressure |
MPa |
2,49 |
2,49 |
2,49 |
2,85 |
2,88 |
2,88 |
Combustion air system (Note 1) |
|
|
|
|
|
|
|
Flow at 100% load |
kg/s |
4,98 |
5,24 |
5,24 |
6,20 |
6,56 |
6,56 |
Temperature at turbocharger intake, max. |
°C |
45 |
45 |
45 |
45 |
45 |
45 |
Air temperature after air cooler (TE 601) |
°C |
55 |
55 |
55 |
55 |
55 |
55 |
Exhaust gas system (Note 2) |
|
|
|
|
|
|
|
Flow at 100% load |
kg/s |
5,13 |
5,40 |
5,40 |
6,38 |
6,75 |
6,75 |
Flow at 85% load |
kg/s |
4,88 |
5,14 |
4,96 |
5,53 |
5,99 |
5,92 |
Flow at 75% load |
kg/s |
4,40 |
4,65 |
4,43 |
4,86 |
5,23 |
5,16 |
Flow at 50% load |
kg/s |
3,10 |
3,26 |
3,71 |
3,41 |
3,69 |
4,05 |
Temperature after turbocharger, 100% load (TE 517) |
°C |
380 |
380 |
380 |
360 |
360 |
360 |
Temperature after turbocharger, 85% load (TE 517) |
°C |
328 |
325 |
336 |
340 |
335 |
335 |
Temperature after turbocharger, 75% load (TE 517) |
°C |
328 |
325 |
345 |
348 |
345 |
355 |
Temperature after turbocharger, 50% load (TE 517) |
°C |
352 |
345 |
315 |
380 |
380 |
340 |
Backpressure, max. |
kPa |
3,00 |
3,00 |
3,00 |
3,00 |
3,00 |
3,00 |
Calculated pipe diameter for 35m/s |
mm |
586 |
601 |
601 |
643 |
662 |
662 |
Heat balance (Note 3) |
|
|
|
|
|
|
|
Jacket water, HT-circuit |
kW |
488 |
510 |
510 |
452 |
480 |
480 |
Charge air, HT-circuit |
kW |
473 |
488 |
488 |
650 |
730 |
730 |
Charge air, LT-circuit |
kW |
375 |
398 |
398 |
420 |
440 |
440 |
Lubricating oil, LT-circuit |
kW |
361 |
390 |
390 |
421 |
432 |
432 |
Radiation |
kW |
110 |
110 |
110 |
110 |
110 |
110 |
Fuel system (Note 4) |
|
|
|
|
|
|
|
Pressure before injection pumps (PT 101) |
kPa |
700±50 |
700±50 |
700±50 |
700±50 |
700±50 |
700±50 |
Engine driven pump capacity (MDF only) |
m³/h |
4,30 |
4,50 |
4,50 |
4,30 |
4,50 |
4,50 |
Fuel flow to engine (without engine driven pump), approx. |
m³/h |
2,90 |
3,10 |
3,10 |
3,40 |
3,60 |
3,60 |
HFO viscosity before engine |
cSt |
16...24 |
16...24 |
16...24 |
16...24 |
16...24 |
16...24 |
HFO temperature before engine, max. (TE 101) |
°C |
140 |
140 |
140 |
140 |
140 |
140 |
MDF viscosity, min |
cSt |
2,0 |
2,0 |
2,0 |
2,0 |
2,0 |
2,0 |
MDF temperature before engine, max. (TE 101) |
°C |
45 |
45 |
45 |
45 |
45 |
45 |
Fuel consumption at 100% load |
g/kWh |
184 |
185 |
185 |
184 |
185 |
185 |
Fuel consumption at 85% load |
g/kWh |
181 |
182 |
181 |
181 |
182 |
181 |
Fuel consumption at 75% load |
g/kWh |
182 |
183 |
182 |
182 |
183 |
182 |
Fuel consumption at 50% load |
g/kWh |
193 |
193 |
191 |
193 |
193 |
191 |
Clean leak fuel quantity, MDF at 100% load |
kg/h |
11,10 |
11,60 |
11,60 |
12,70 |
13,50 |
13,50 |
Clean leak fuel quantity, HFO at 100% load |
kg/h |
2,20 |
2,30 |
2,30 |
2,50 |
2,70 |
2,70 |
Lubricating oil system |
|
|
|
|
|
|
|
Pressure before bearings, nom. (PT 201) |
kPa |
500 |
500 |
500 |
500 |
500 |
500 |
Suction ability main pump, including pipe loss, max. |
kPa |
30 |
30 |
30 |
30 |
30 |
30 |
Priming pressure, nom. (PT 201) |
kPa |
50 |
50 |
50 |
50 |
50 |
50 |
Suction ability priming pump, including pipe loss, max. |
kPa |
30 |
30 |
30 |
30 |
30 |
30 |
Temperature before bearings, nom. (TE 201) |
°C |
63 |
63 |
63 |
63 |
63 |
63 |
Temperature after engine, approx. |
°C |
78 |
78 |
78 |
78 |
78 |
78 |
Pump capacity (main), engine driven |
m³/h |
78 |
81 |
81 |
78 |
81 |
81 |
Pump capacity (main), stand-by |
m³/h |
67 |
70 |
70 |
67 |
70 |
70 |
Priming pump capacity, 50Hz/60Hz |
m³/h |
15,0 / 18,0 |
15,0 / 18,0 |
15,0 / 18,0 |
15,0 / 18,0 |
15,0 / 18,0 |
15,0 / 18,0 |
Oil volume, wet sump, nom. |
m³ |
1,60 |
1,60 |
1,60 |
1,60 |
1,60 |
1,60 |
Oil volume in separate system oil tank, nom. |
m³ |
3,90 |
4,10 |
4,10 |
4,50 |
4,70 |
4,70 |
Oil consumption (100% load), approx. |
g/kWh |
0,50 |
0,50 |
0,50 |
0,50 |
0,50 |
0,50 |
Crankcase ventilation flow rate at full load |
l/min |
990 |
990 |
990 |
1080 |
1080 |
1080 |
Crankcase ventilation backpressure, max. |
kPa |
0,40 |
0,40 |
0,40 |
0,40 |
0,40 |
0,40 |
Oil volume in turning device |
liters |
8,5...9,5 |
8,5...9,5 |
8,5...9,5 |
8,5...9,5 |
8,5...9,5 |
8,5...9,5 |
Oil volume in speed governor |
liters |
1,90 |
1,90 |
1,90 |
1,90 |
1,90 |
1,90 |
Cooling water system |
|
|
|
|
|
|
|
High temperature cooling water system |
|
|
|
|
|
|
|
Pressure at engine, after pump, nom. (PT 401) |
kPa |
250 + static |
250 + static |
250 + static |
250 + static |
250 + static |
250 + static |
Pressure at engine, after pump, max. (PT 401) |
kPa |
530 |
530 |
530 |
530 |
530 |
530 |
Temperature before cylinders, approx. (TE 401) |
°C |
85 |
85 |
85 |
85 |
85 |
85 |
HT-water out from engine, nom (TE402) (single stage CAC) |
°C |
96 |
96 |
96 |
96 |
96 |
96 |
HT-water out from engine, nom (TE432) (two stage CAC) |
°C |
96 |
96 |
96 |
96 |
96 |
96 |
Capacity of engine driven pump, nom. |
m³/h |
60 |
60 |
60 |
60 |
60 |
60 |
Pressure drop over engine, total (single stage CAC) |
kPa |
100 |
100 |
100 |
100 |
100 |
100 |
Pressure drop over engine, total (two stage CAC) |
kPa |
150 |
150 |
150 |
150 |
150 |
150 |
Pressure drop in external system, max. |
kPa |
60 |
60 |
60 |
60 |
60 |
60 |
Pressure from expansion tank |
kPa |
70...150 |
70...150 |
70...150 |
70...150 |
70...150 |
70...150 |
Water volume in engine |
m³ |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
Low temperature cooling water system |
|
|
|
|
|
|
|
Pressure at engine, after pump, nom. (PT 451) |
kPa |
250 + static |
250 + static |
250 + static |
250 + static |
250 + static |
250 + static |
Pressure at engine, after pump, max. (PT 451) |
kPa |
530 |
530 |
530 |
530 |
530 |
530 |
Temperature before engine (TE 451) |
°C |
25 ... 38 |
25 ... 38 |
25 ... 38 |
25 ... 38 |
25 ... 38 |
25 ... 38 |
Capacity of engine driven pump, nom. |
m³/h |
60 |
60 |
60 |
60 |
60 |
60 |
Pressure drop over charge air cooler |
kPa |
35 |
35 |
35 |
35 |
35 |
35 |
Pressure drop over oil cooler |
kPa |
30 |
30 |
30 |
30 |
30 |
30 |
Pressure drop in external system, max. |
kPa |
60 |
60 |
60 |
60 |
60 |
60 |
Pressure from expansion tank |
kPa |
70 ... 150 |
70 ... 150 |
70 ... 150 |
70 ... 150 |
70 ... 150 |
70 ... 150 |
Starting air system (Note 5) |
|
|
|
|
|
|
|
Pressure, nom. |
kPa |
3000 |
3000 |
3000 |
3000 |
3000 |
3000 |
Pressure at engine during start, min. (20°C) |
kPa |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
Pressure, max. |
kPa |
3000 |
3000 |
3000 |
3000 |
3000 |
3000 |
Low pressure limit in air vessels |
kPa |
1800 |
1800 |
1800 |
1800 |
1800 |
1800 |
Air consumption per start |
Nm³ |
2,10 |
2,10 |
- |
2,10 |
2,10 |
- |
Air consumption per start without propeller shaft engaged |
Nm³ |
- |
- |
2,10 |
- |
- |
2,10 |
Air consumption with automatic start and slowturning |
Nm³ |
- |
- |
- |
3,00 |
3,00 |
3,00 |
Air consumption per start with propeller shaft engaged |
Nm³ |
- |
- |
3,40 |
- |
- |
3,40 |
Air consumption with automatic start and high inertia slowturning |
Nm³ |
- |
- |
- |
4,60 |
4,60 |
4,60 |
Notes:
Note 1 At ISO 3046-1 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Tolerance 5%.
Note 2 At ISO 3046-1 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Flow tolerance 5% and temperature tolerance 10°C.
Note 3 At ISO 3046-1 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Tolerance for cooling water heat 10%, tolerance for radiation heat 30%. Fouling factors and a margin to be taken into account when dimensioning heat exchangers.
Note 4 According to ISO 3046/1, lower calorific value 42 700 kJ/kg, with engine driven pumps (two cooling water + one lubricating oil pumps). Tolerance 5%. Load according to propeller law for mechanical propulsion engines (ME).
Note 5 Automatic (remote or local) starting air consumption (average) per start, at 20°C for a specific long start impulse (DE/AUX: 2...3 sec, CPP/FPP: 4...6 sec) which is the shortest time required for a safe start.
ME = Engine driving propeller, variable speed
AE = Auxiliary engine driving generator
DE = Diesel-Electric engine driving generator
Subject to revision without notice.
Ко всему вышеуказанному оборудованию мы поставляем СЗЧ согласно каталожным номерам производителя.