Headway® Voyage Data Recorder
Voyage data recorder (VDR), popular name-black box, is used for recording all kinds of navigation information. The recorded data is used for analyzing causes of major and minor incidents happened during ships’ voyage.
Headway® Voyage Data Recorder System Chart
Headway® VDR&S-VDR Components
Main Cabinet
Based on the real-time embedded operating system of Vxworks, the system is more reliable, handy and adaptable to all kinds of installations on board. With a power of 25W without any ventilation fans, the Main Cabinet Unit body is designed to be closed, no dust to enter. There are many interfaces with PNP function. It can be configured online, with easy access to debug and random real-timemonitor function. It is more convenient for data of download.
The system is stable, needless of special person for check. The Main Cabit Unit is designed to be closed and can work normally even in severe environment. With a system power of only 25W, needless of ventilation, more reliable as a result. The system’s spare parts are all self-developed and manufactured,be in strong position to provide the permanent availabilities. You can enjoy these quality and inexpensive products with excellent global service network worldwide.
The main and supplementary power supply
The main and supplementary power supply work with 110V/220V 50Hz/60Hz without any manual configuration. The control panel ensures that the machine can continue to work with supplementary power of 24V when the main power supply fails.
After the ship loses its emergency power, the battery will supply the power and go on to record audio data for over 2 hours. The maintenance-free batteries can be used for 3 years.
AC input range: 110V/220V 50Hz/60Hz
DC input range: 24v
Remote Acquisition Unit
As to the device without standard digital interface, the editable signal gathering module can be installed at the scene to obtain necessary digit and analog data.
Remote Alarm Unit
It conducts round-the-clock monitor of the VDR with acoustic and light alarm indications, the liquid display will enable you to more easily get rid of faults. The mergency backup function is able to record 12 hours data for later inspection, the backup maximum can be 30 copies.
Microphone unit
It has an embedded design, elegant outer appearance, easy to install with self-inspection function in order to avoid the failure of audio signals gathering due to the damage of microphone. Its inbuilt amplifying function enables the transmission of high-fidelity audio signal in a long distance.
Replay Software
With a friendly human-machine interface, this software is easy to use and install. The online replay function can monitor the real-time operating status of the relevant devices in the bridge so as to enable the captain to know the commands given by the operators in the bridge and to send the data back to the headquarters for analysis. It is easy to download and replay the data of the PDC and to investigate the incidents and to analyze the functioning monitor. The replay function can also be a valuable tool for crew training. This software ensures complete retrieval and display of all recorded data.
Reliable Protective Data Capsule
The self-developed Protective Data Capsule is more inexpensive and competitive.
The Protective Data Capsule is a special one with high technology, which can be produced by only a few manufacturers in the world. IEC61996 specifies that the final recording medium for the VDR must be installed in the capsule in accordance with the following standards:
- Penetration: an object with a prick of 100mmdiameter and a weight of 250kg falling from 3 meters above;
- Impact: 50g semi-sine pulses for continuous 11 ms;
- Fire-resistance: 260°C low temperature for 10 hours, and 1100°C high temperature for 1 hour;
- Pressure in deep sea: 30 days at 60 Mpa (6,000 meters depth) under sea and 30days dipping.
Float-free Protective Data Capsule
This multi-used float-free storage unit includes an S-VDR storage medium and a conventional GMDSS satellite position indicator beacon, also called EPIRB. The Float-free Storage Unit includes all the updated 12hours data. After the protective data capsule falls into water, it will keep the valid information of the S-VDR and automatically float on the water surface. There is no need to look for it under the water. It is more convenient to locate and salvage it through satellite.
- Transmission of Ethernet Signal
- Solid storage medium of 2-9 GB
- Two 24W power input-lines and 4 signal-lines to make it easier to float and detach
- Integral 406 MHz with 121.5 MHz GPS satellite beacon 7 days’ lifetime of battery (minimum)
- Integral automatic pressure-release device
- Salvage hook to make salvage more convenient
We supply spare parts to all the above mentioned equipment in accordance with the catalogue number provided by the manufacturer.