6M25
Страницы каталога СЗЧОписание двигателя:
6M25 представляет собой шестицилиндровый четырехтактный дизельный двигатель, нереверсивный, с турбонаддувом, промежуточным охлаждением и с прямым впрыском топлива.
Технические характеристики
| Technical data 6M25 | |||
| Performance Data | |||
| Maximum continuous rating acc. ISO 3046/1 | kW | 1900 | 2000 |
| Speed | 1/min | 720 | 750 |
| Minimum speed | 1/min | 240 | 250 |
| Brake mean effective pressure | bar | 25,8 | 26,1 |
| Charge air pressure | bar | 3,1 | 3,2 |
| Firing pressure | bar | 205 | 210 |
| Combustion air demand (ta = 20°C) | m³/h | 10800 | 11505 |
| Specific fuel oil consumption | |||
| n = const1) 100% | g/kWh | 186 | |
| 85% | g/kWh | 184 | |
| 75% | g/kWh | 184 | |
| 50% | g/kWh | 193 | |
| Lubricating oil consumption 2) | g/kWh | 0,6 | |
| NOx -emission 6) | g/kWh | 9,6 | |
| Turbocharger type | KBB HPR6000 | ||
| Fuel | |||
| Engine driven booster pump | m³/h /bar | 1,5/3 | |
| Stand-by booster pump | m³/h /bar | 2,2/10 | 2,3/10 |
| Mesh size MDO fine filter | mm | 0,025 | |
| Mesh size HFO automatic filter | mm | 0,01 | |
| Mesh size HFO fine filter | mm | 0,034 | |
| Lubricating Oil | |||
| Engine driven pump | m³/h /bar | 89/10 | 93/10 |
| Independent pump | m³/h /bar | 45/10 | |
| Working pressure at engine inlet | bar | 4 - 5 | |
| Independentsuction pump | m³/h /bar | 57/3 | |
| Primimg pump pressure/suction pump | m³/h /bar | 6,6/8/5 | |
| Sump tank content/dry sump content | m³ | 2,6 | 2,7 |
| Temperature at engine inlet | ⁰C | 60 - 65 | |
| Temperature controller NB | mm | 80 | |
| Double filter NB | mm | 80 | |
| Mesh size double filter | mm | 0,08 | |
| Mesh size automatic filter | mm | 0,03 | |
| Fresh water cooling | |||
| Engine content | m³ | 0,4 | |
| Pressure at engine inlet min/max | bar | 4,6/6,0 | |
| Headertank capacity | m³ | 0,2 | |
| Temperature at engine outlet | ⁰C | 80 - 90 | |
| Two-circuit system | |||
| Engine driven pump HT | m³/h /bar | 40/4,5 | |
| Independent pump HT | m³/h /bar | 40/4,0 | |
| HT-controller NB | mm | 80 | |
| Water demand LT-charge air cooler | m³/h | 40 | |
| Temperature at LT-charger air cooler inlet | ⁰C | 38 | |
| Heat dissipation | |||
| Specific jacket water heat | kJ/kW | 500 | |
| Specific lube oil heat | kJ/kW | 490 | |
| Lube oil cooler | kW | 259 | 273 |
| Jacket water | kW | 264 | 278 |
| Charge air cooler (HT stage)3) | kW | 521 | 576 |
| Charge air cooler (LT stage)3) (HT stage after engine) | kW | 181 | 196 |
| Heat radiation engine | kW | 85 | |
| Exhaust gas | |||
| Silencer/spark arrester NB 25 dBA | mm | 500/500 | |
| Pipe diameter NB after turbine | mm | 500 | |
| Maximum exhaust gas pressure drop | bar | 0,03 | |
| Exhaust gas temp after turbine (25°C intake air) 5) | ⁰C | 323 | 333 |
| Exhaust gas mass flow (25°C intake air)5) | kg/h | 13345 | 14220 |
| Starting air | |||
| Starting air pressure max. | bar | 30 | |
| Minimum starting air pressure | bar | 7 | |
| Air consumption per start4) | Nm³ | 0,8 | |
| Max. crankcase pressure, nominal diameter ventilation pipe | mmWs/ mm | 15/80 | |
| 1) Reference conditions: LCV = 42700 kJ/kg ambient temperature 25 ⁰C | |||
| charge air coolant temperature 25 ⁰C tolerance 5 % | |||
| + 1 % for engine driven pump | |||
| 2) Standard value tolerance ± 0,3 g/kWh related on full load | |||
| 3) Charge air heat based on 45 ⁰C ambienttemperature | |||
| 4) Preheated engine | |||
| 5) Tolerance 10 % rel. humidity 60 % | |||
| 6) MARPOL 73/78 Annex VI, Cycle E2, E3, D2 |
Страницы каталога СЗЧ